Rcbo circuit breaker price
I have found results from10000+products and3000+suppliers aboutRcbo circuit breaker price
Residual Current Operated Circuit Breaker Albo RCBO 10mA 30mA 100mA 300mA
Wholesale Price DIN Rail Mounting RCBO, RCCB, MCB Residual Current Circuit Breaker
Leakage Circuit Breaker RCBO MCB Short Circuit Overload Leakage Protection
Good Price Zhejiang Fixed Cnjuho by Cartons Gv2me RCBO Electrical Circuit Breaker
CNC Ycb9rl-100 1p+N Leakage Circuit Breaker 100A ELCB RCCB/RCBO Price
Manufacturers Price 4p RCCB RCBO RCD Residual Current Circuit Breaker
Manufacturers Price 1p+N RCCB RCBO RCD Residual Current Circuit Breaker
Manufacturers Price 1pn 63A RCCB RCBO RCD Residual Current Circuit Breaker
Manufacturers Price 3pn 63A RCCB RCBO Residual Current Circuit Breaker
B Type RCCB, RCBO Residual Current Circuit Breaker CE, CB Approvals
18mm Width RCBO 1p+N 40A/30mA Earth Leakag Circuit Breaker
Residual Current Circuit Breaker with Over Current Protetion (RCBO)
Sg RCBO 250A 1pn Thermal-Magnetic Dual-Break Wholesale-Price Residual Current Circuit Breaker 415V
Etek ETL3-63 3p+N 50A Residual Current Advanced Protection Etek RCBO Circuit Breaker with Factory Price
Etek Low Voltage Breakers B-Type 10ka ETL5-63b RCBO 1p+N 50A Circuit Breaker with Factory Price
Factory Price 35mm DIN Rail Etek Ekl3-63h 1p+N 40A RCBO Safety-First Overcurrent Circuit Breaker
Good Price Ekl5-63b 3p+N 25A Etek Advanced Overcurrent Protection High-Performance RCBO Circuit Breaker
1-4p Air Singi RCBO Price Mini Circuit Breaker with High Quality Sg65le-63
Factory Price Low Voltage Breakers Singi Mini Miniature Circuit Breaker RCBO Sg65le-63
Hot Sale 1-4p CE Approved Singi Mini RCBO Price Electronic Circuit Breaker Sg65le-63
Factory Price CB Approved Electric Type Singi RCBO Electrical Electronic Circuit Breaker Sg65le-63
MCB Singi MCCB Price Electrical RCBO Miniature Circuit Breaker Hot Sale Sg65le-63
Factory Price Singi Overcurrent Protection 1p-4p 6ka Electrical Circuit Breaker RCBO Dz47le-63
Dz47ples-40 1p+N RCBO Earth Leakage Circuit Breaker (Dpn 1p+N RCBO Breaker)
Sourcing guidance for Rcbo Circuit Breaker Price
How to choose the right RCBO based on technical specifications?
Selecting an RCBO (Residual Current Breaker with Overcurrent protection) requires matching the device to your specific electrical load. You must prioritize the Rated Current (In), typically ranging from 6A to 63A, and the Rated Residual Operating Current (IΔn), where 30mA is the standard for life safety and 100mA/300mA is used for fire protection. Additionally, verify the Breaking Capacity (Icn); for residential use, 6kA is usually sufficient, but industrial applications may require 10kA or higher to ensure the device can safely interrupt a short circuit without exploding.
What are the critical compliance standards for RCBOs in international trade?
Compliance is non-negotiable for electrical components. Ensure the products adhere to IEC/EN 61009-1, which is the international benchmark for RCBOs. For specific markets, look for the CE mark (Europe), UKCA (UK), or UL certification (North America). If you are sourcing from China via Made-in-China.com, always request a valid CCC (China Compulsory Certificate) and a CB Test Certificate to facilitate smoother customs clearance and ensure local grid compatibility.
How does the 'Type' of RCBO affect its performance and price?
The price of an RCBO is heavily influenced by its tripping characteristic. Type AC is the most economical but only detects sinusoidal AC residual currents. Type A is more versatile as it detects both AC and pulsating DC components, making it essential for modern homes with electronics and LED lighting. For specialized industrial needs involving frequency converters or EV chargers, you may require Type B, which is significantly more expensive but offers the highest level of protection against smooth DC faults.
What factors influence the pricing of RCBOs in bulk procurement?
RCBO pricing is driven by internal component quality, such as the use of silver alloy contacts versus copper, and the complexity of the electromagnetic release. Electronic RCBOs are generally cheaper and smaller (1P width) but depend on line voltage to trip, whereas Electromagnetic RCBOs are more robust and safer as they trip even if the neutral wire is lost. When negotiating on Made-in-China.com, expect a 15-25% price reduction for volumes exceeding 1,000 units, but beware of prices significantly below market average as they may indicate recycled plastics or inferior copper windings.
Cross-Border Procurement Risks and Strategies for RCBOs
How can I mitigate the risk of receiving counterfeit or sub-standard electrical goods?
Always conduct a factory audit or use a third-party inspection service (like SGS or Intertek) before the final balance payment. On Made-in-China.com, prioritize 'Audited Suppliers' who have verified business licenses and production capabilities. Request a pre-shipment sample from the actual production batch to test the tripping time and current accuracy using a calibrated RCD tester.
What are the best practices for shipping sensitive electrical components internationally?
RCBOs contain delicate calibration mechanisms. Ensure the supplier uses individual inner boxes and high-quality 5-layer corrugated outer cartons with moisture-proof lining. For sea freight, specify FCL (Full Container Load) if possible to reduce handling shocks, or ensure palletization with shrink-wrap for LCL (Less than Container Load) shipments to prevent crushing and humidity damage.
How should I handle payment security and trade terms (Incoterms)?
For new suppliers, use Secured Trading services provided by the platform to ensure funds are only released upon proof of shipment. Regarding Incoterms, FOB (Free On Board) is recommended for experienced buyers to maintain control over freight costs, while DDP (Delivered Duty Paid) is better for those who want the supplier to handle all import duties and local VAT/GST complications.
What should I look for in a supplier's after-sales policy for circuit breakers?
Reliable suppliers should offer a warranty period of 18 to 24 months. Ensure the contract includes a defective rate clause; if the failure rate exceeds 1%, the supplier should provide free replacements or a credit note for the next order. Technical support, including wiring diagrams and installation manuals in English, should be provided as standard.





























