SourcingAI

U bend copper fitting

I have found results from10000+products and3000+suppliers aboutU bend copper fitting

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Straight Copper Pipe
Air Conditioning Accessories
Type: Top-Freezer
Type: Equal
Type: Socket Union
Standard: GB
Tolerance: +/-0.10mm
Application: Home
Certification: ISO9001
ventilation mode: mechanical ventilation
Shape: Round
Grade: TP2
State: Soft
Customized: Customized
Color: Red
Home Refrigerator & Freezer
Cooling/Heating: Cooling/Heating
Condition: New
Capacity: 200-300L
Door: Single Door
Installation: Free-Standing
Power Source: Electricity
Material: Plastic
Temperature Type: Single-Temperature
Defrost Type: Auto Defrost
Climate Type: SN
Connection: Welding
Head Code: Round
Angle: 45 Degree
Technics: Forged
Lateral: 90°Tee
Pressure Rating: 6000LBS
Technique: Forged
Nominal Diameter: DN15
Wall Thickness: Sch20
Standard: ASTM B88
Standard: ASTM B837
Standard: ASTM B306
Standard: ASTM B883
Standard: ASTM B819
Standard: AS
Standard: GB3289.37,3298.38-82
Application: Water Tube
Certification: TUV
Certification: ROHS
Certification: ISO
Certification: CE
Certification: RoHS
Certification: GS
Certification: API
Certification: ASME
Certification: GB
Shape: Equal
Shape: Equal Tee
Color: Yellow
Usage: Room
Material: Copper
Connection: Press Connection
Angle: 180 Degree
Angle: 90 Degree
Technics: Pushing

Sourcing guidance for U Bend Copper Fitting

What are the key technical specifications to consider when sourcing U Bend Copper Fittings?

Buyers must prioritize material purity, typically requiring C12200 Phosphorus-Deoxidized Copper (99.9% Cu) to ensure excellent thermal conductivity and corrosion resistance. Key dimensions include Outer Diameter (OD), Wall Thickness, and the Center-to-Center (C-C) distance. For HVAC and refrigeration, a wall thickness of 0.5mm to 1.5mm is standard, but it must be verified against the working pressure requirements of the specific refrigerant used (e.g., R410A requires higher pressure ratings).

Which international compliance standards are mandatory for these fittings?

To ensure safety and interoperability, fittings should comply with ASME B16.22 (Wrought Copper and Copper Alloy Solder-Joint Pressure Fittings) or EN 1254-1 (Copper and copper alloys - Plumbing fittings). For refrigeration applications, look for UL 207 certification. If the fittings are intended for potable water systems, NSF/ANSI 61 certification is essential to guarantee no lead or harmful contaminants leach into the water.

How can I evaluate the manufacturing quality and durability of the U-bends?

Request a Hydrostatic Pressure Test report to confirm the burst pressure exceeds operational limits. Inspect the bending radius for signs of thinning or wrinkling; high-quality U-bends should maintain a uniform wall thickness throughout the curve. Additionally, ensure the ends are burr-free and perfectly round to facilitate seamless brazing or soldering, preventing leaks in high-vibration environments like heat exchangers.

What are the typical usage scenarios for U Bend Copper Fittings in B2B procurement?

These fittings are primarily used in Heat Exchanger manufacturing, HVAC (Heating, Ventilation, and Air Conditioning) systems, and Condenser/Evaporator coils. They are also critical in Solar Thermal Collectors and Medical Gas Pipeline Systems. For industrial cooling, they are often integrated into chiller units where compact 180-degree turns are required to maximize surface area in a limited space.

Cross-Border Purchasing Considerations for Copper Components

How do I manage the risk of price volatility in copper procurement?

Copper is a LME (London Metal Exchange) traded commodity, meaning prices fluctuate daily. Professional buyers should negotiate a pricing formula with suppliers based on the LME spot price plus a fabrication fee. Avoid fixed-price contracts for long-term orders unless you are willing to pay a premium for the supplier to hedge the risk.

What are the best practices for shipping and protecting copper fittings during transit?

Copper is prone to oxidation (patina) and physical deformation. Ensure the supplier uses vacuum packaging or moisture-proof plastic bags with desiccant. For bulk shipments, fittings should be packed in reinforced corrugated boxes with internal dividers and secured on fumigated wooden pallets to prevent crushing during sea freight.

How can I verify the credibility of a supplier on Made-in-China.com?

Prioritize Audited Suppliers who have undergone on-site inspections by third-party agencies like SGS or Bureau Veritas. Check their Business Type (Manufacturer vs. Trading Company) and request a Material Test Certificate (MTC) for the specific batch of copper used. Reviewing their export history to your target region can also indicate their familiarity with your local customs and standards.

What transaction security measures should be taken for large B2B orders?

Utilize Secured Payment services provided by the platform to ensure funds are only released upon proof of shipment. For first-time large orders, it is highly recommended to hire a third-party inspection service (like V-Trust or QIMA) to perform a Pre-Shipment Inspection (PSI) to verify quantity, dimensions, and packaging before the final balance is paid.

Related queries